显示标签为“BET surface area”的博文。显示所有博文
显示标签为“BET surface area”的博文。显示所有博文

2016年1月7日星期四

Specific Surface Area and Pore Size Distribution Analyser Exported to Canada


Gold APP Instruments Corporation China had export one set volumetric specific surface area and porosity analyzer to Canada catalyst manufacturer--Manson Environmental Corporation. This is the first set Chinese brand analyzer came into Canada market.

 

Manson Environmental Corporation is an inorganic chemicals manufacturer in Oakville. This private company was founded in 1986.

 

Gold APP Instruments China also produce gas pycnometer analyzer for true density, the open and closed pore cells testing; high pressure volumetric adsorption analyzer for PCI, TPD, adsorption/ desorption isotherms testing. Welcome email to sales@jinaipu.com for more details.

2012年12月19日星期三

automated V-Sorb 4800S surface area determination by static nitrogen sorption

V-Sorb 4800S specific surface area analyzer introduction


V-Sorb 4800S is Gold APP self-developed surface area and porosity analyzer which utilizes static volumetric. Compared with other companies analyzers, multi pioneered techs make instruments performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in domestic competitors and partial applications surpass foreign instruments. Products designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers real demands. The high cost performance of V-Sorb 4800S easily ensure your investment profits and flexible equipped peripheral can satisfy different users requests.



V-Sorb 4800S specific surface area analyzer parameters

Analysis Method: static volumetric nitrogen adsorption

Versatility: Adsorption and desorption isothermal curve analysis, Single and multi point BET method specific surface area analysis, T-plot method external surface area analysis, True density analysis, BJH mesopore analysis, BJH total pore volume and porosity analysis, T-plot micropore analysis, MP micropore analysis, Langmuir surface area analysis

Measuring Ranges: 0.01m2/g to no known upper limit(specific surface area); 0.35-2nm (micropore); 2-400nm (mesopore and macropore)

Accuracy: repeatability errors 1.5%

Vacuum System: V-sorb unique assembling-installed manifolds and electromagnetically operated valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life

Coolant Level Controller: V-sorb original coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change

Analysis Types: N2 and N2+He two types available

Gas Dosing: Can choose He (99.999%) to dose the cold volume, not only He+Empty cell one type

Control System: programmable controller electromagnetically operated valve system with high integration and strong anti-interference ability, enhance instruments stability

Sample Ports: four samples analyzing and four degassing concurrently

Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, two transducers 0-1000Torr (0-133Kpa)

Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.15% of real reading, better than 0.15% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)

Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.995

Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)

Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pumps start/stop 

Sample Types: powders, particle, fiber, flakes and other materials

Adsorbate Gas: high purity nitrogen(99.999%, Ar, Kr etc. optional

Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability

Data Reduction: Windows®-base independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports

Specifications: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth 23.62 inches (60cm); 132 pound (60kg)

 
V-Sorb 4800S specific surface area analyzer features


A: Vacuum System

1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.

3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

 
B: Control System

1. Industry used programmable controller electromagnetically operated valve system, strong anti-interference ability, convenient for installation and uninstallation.

2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.


C. Measures for Improving Accuracy

1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.15% of real reading, better than 0.15% of F.S. (full-scale).

2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

3. Unique assembling-installed manifolds system, decrease connecting points and reduce leak rate apparently.

4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.

5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducers macro-change.


D. Data Acquisition and Reduction

1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzers applications extension and interconnection, can also conveniently switched to RS232 and USB modes.

2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.

 

V-Sorb 4800S specific surface area analyzer application

 
1. Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.

2. Product quality control for powder materials related corporations.

3. Research institutes, universities for BET theory teaching.

4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.

5. Other researches concern surface area performance.



 

For more details, pls. contact us:



Tel.: 86-10-82133318 #810

Mobile: 86-18210009838


Skype: Gold-APP-Instruments

V-Sorb 2800S specific surface area determination instrument for lab and research use

V-Sorb 2800S specific surface area analyzer introduction


V-Sorb 2800S is Gold APP self-developed surface area and porosity analyzer which utilizes static volumetric. Compared with other companies analyzers, multi pioneered techs make instruments performance much better, heighten accuracy and consistence of results, enhance measurement stability, all these lead to a leading level in domestic competitors and partial applications surpass foreign instruments. Products designed from the user perspective and equipped with fully automated operation, user-friendly interface makes it easy to learn, imported accessories assure stability and prolong life. Perfect design, sophisticated production and strict testing guarantee to meet customers real demands. The high cost performance of V-Sorb 2800S easily ensure your investment profits and flexible equipped peripheral can satisfy different users requests.



V-Sorb 2800S specific surface area analyzer parameters


Analysis Method: static volumetric nitrogen adsorption

Versatility: Adsorption and desorption isothermal curve analysis, Single and multi point BET method specific surface area analysis, Average particle diameter estimation, T-plot method external surface area analysis, True density analysis

Measuring Ranges: 0.01m2/g to no known upper limit(specific surface area)

                  0.35 to 400nm (pore size)

Accuracy: repeatability errors 1.5%

Vacuum System: V-sorb unique assembling-installed manifolds and electromagnetically operated valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life

Coolant Level Controller: V-sorb original coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change

Analysis Types: N2 and N2+He two types available

Gas Dosing: Can choose He (99.999%) to dose the cold volume, not only He+Empty cell one type

Sample Treatment: the whole treatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night

Control System: programmable controller electromagnetically operated valve system with high integration and strong anti-interference ability, enhance instruments stability and life

Sample Ports: two samples analyzing and two samples degassing concurrently

Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)

Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.15% of real reading, better than 0.15% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)

Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.995

Ultimate Vacuum: 4x10-2Pa (3x10-4 Torr)

Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pumps start/stop 

Sample Types: powders, particle, fiber, flakes and other materials

Adsorbate Gas: high purity nitrogen99.999%, Ar, Kr etc. optional

Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability

Data Reduction: Windows®-base independent developed Gold APP softwareTM, perfect versatility, produced full featured and multi-model reports



V-Sorb 2800S specific surface area analyzer features


A: Vacuum System

1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.

2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.

3. Germany imported bipolar vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).

B: Control System

1. Industry used programmable controller electromagnetically operated valve system, strong anti-interference ability, convenient for installation and uninstallation.

2. Separated analysis and treatment manifolds can prevent foreign matter to contaminate manifolds in sample treatment.

C. Measures for Improving Accuracy

1. Imported silicon thin film capacitive pressure transducer, accuracy can reach 0.15% of real reading, better than 0.15% of F.S. (full-scale).

2. 0-10Torr (optional) and 0-1000Torr dual pressure transducers, sectional measurement in pressure range can reduce errors in low vacuum, 0-10Torr silicon thin film transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).

3. Unique assembling-installed manifolds system, decrease connecting points and reduce leak rate apparently.

4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change.

5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducers macro-change.


D. Data Acquisition and Reduction

1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzers applications extension and interconnection, can also conveniently switched to RS232 and USB modes.

2. Multi calculating methods for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.



V-Sorb 2800S specific surface area analyzer application


1. Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.

2. Product quality control for powder materials related corporations.

3. Research institutes, universities for BET theory teaching.

4. Fuel cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.

5. Other researches concern surface area performance.




For more details, pls. contact us:



Tel.: 86-10-82133318 #810

Mobile: 86-18210009838


Skype: Gold-APP-Instruments

F-Sorb 2400CE fully automatic BET surface area analyzer for particle and porous materials

F-Sorb 2400CE BET surface area analyzer introduction


F-Sorb X400CE series surface area and porosity analyzers are new generation instruments which were researched and developed by Gold APP Corporation and China weapons institute. Gold APP is the ONLY one domestic manufacturer can produce no user involvement, fully-auto and highly intelligent analyzers which can match international standards and trends. Innumerable independently patented techs make Gold APP instruments enjoy great popularity at home and abroad. A high level of precision and resolution, complicity of operation, speed, compact size, and their stability guarantee our analyzers equally appropriate to industry quality control, institutes, universities and laboratories. The weapons systems high demands and imported parts with original packaging had greatly improved instruments reliability and life. The high cost performance of F-Sorb X400CE series analyzers easily ensure your investment profits and flexible equipped peripheral can satisfy different users demands.


F-Sorb 2400CE adopts speed and efficient dynamic nitrogen adsorption principle, is an expert for contrast reference method and BET method analysis. BET method is universally recognized and the most commonly used way for nitrogen adsorption surface area analysis. No need of reference materials (RM) and utilizes sorption with incorporates multilayer coverage to calculate surface area. Experimental data do not vary with different sample types, high accuracy and quite scientific make F-Sorb 2400CE be a desirable for quality control in production field, research institutes and universities.



F-Sorb 2400CE BET surface area analyzer parameters


Measuring Method: contrast reference method, single and multi point BET method, Langmuir method, average particle size estimate, carbon black external surface area analysis, adsorption constant C analysis

Measuring Ranges: 0.01 m2/g to no known upper limit (specific surface area)

Accuracy: repeatability errors ≤2%

Traffic Adjust: Gold APP patented F-Sorb micro stepping motor traffic can realize traffic auto-adjust for every P/Po point in BET analysis; traffic value auto-collected by software and real-time displayed in interface

Quantitative Dosing: patented F-Sorb quantitative pipe TM desorbs automatically, realized auto dosing for sample desorption isotherm, manual pipeline switch is not required

Manifolds’ Sealing: high vacuum system with stainless steel manifolds, sound sealing performance can eliminate errors caused by gas molecules permeation

Sample Types: powders, particle, fiber, flakes and other species

Sample Ports: 4 samples simultaneously

Analysis Gases: high purity (99.99%) He as carrier; N2 (99.99%) as adsorbate; Ar, Kr etc. are optional 

Time: about 5 minutes for every P/Po point’s adsorption and desorption; analysis data will present automated by Gold APP softwareTM

Pressure: atmospheric pressure, no need vacuum, save experiment time

Data Acquisition: high precision and integration chip, minimal errors, strong anti-interference ability

Data Reduction: Windows®-base independently developed Gold APP softwareTM, perfect versatility, ease of use and multi-model data reduction reports

Operation System: multifunctional, fully automated, highly intelligent operation system



F-Sorb 2400CE BET surface area analyzer features:


Domestic first fully automated and intelligent analyzer; farewell to complex manual operation; minimal user intervention; promote efficiency; F-Sorb 2400CE had improved a lot besides F-Sorb 1400CE outstanding features. 


A. Structure Design

1. Stainless manifolds system is much better than plastic manifolds, obviously enhances sealing performance, eliminates errors caused by gas molecules permeation, no ageing for manifolds, increase reliability and prolong life, more appropriate for humid environment.



B. Control System

1. Integrated multifunctional control system; motor screw rod lifting system ensures Dewar stability.

2. Innovated balanced bridge circuit greatly improves signal voltage sensitivity, as well as achieves auto balance of signal zero drift.

3. Fully-auto operation, minimal operator involvement and work efficiency improved.


C. Data Acquisition and Reduction

1. High precision data acquisition and signal amplification, high integrated A/D transformation system, strong anti-interference ability and high real time, can reduce environmental influence on analysis procedures.

2. Utilize super sensitive thermal conductivity detection and balance system can increase detectable signal range; zero drift auto calibration system enhances stability and accuracy.

3. Independently innovated Windows® compatible software, versatile applications, flexible customer-tailor interface, ease of use; self developed data reduction module can efficiently eliminate system errors and improve precision.

4. Customer made data reports and diversified data calculation models are convenient for data analyzing; powerful data archiving and searching capacity helps a lot for data management.


D. Analysis Optimize

1. Multi analysis methods, no need to convert operations frequently, all set in dedicated software.

2. Contrast reference method and BET method can switch freely, simplify operation steps and improve measurement efficiency.

3. Pioneered gas amount auto-adjust system brings extremely accurate, stable and no user intervention analysis.

4. Can be upgraded to F-Sorb 3400CE.



F-Sorb 2400CE BET surface area analyzer applications


1. Super micro powder, nanomaterials, particle and fiber shaped specific surface area analysis.

2. Product quality control for powder species related corporations.

3. Research institutes, universities for BET theory teaching.

4. Full cells, catalysts, additives, adsorbent, ceramics, magnetic materials, energy storage materials etc.

5. Other researches concern surface area performance.
 
For more details, pls. contact us:
Tel.: 86-10-82133318 #810
Mobile: 86-18210009838
Skype: Gold-APP-Instruments